Install an MPC Line Card and MIC in a Juniper MX480

Models covered: MX480, MPC7E-MRATE, MPC10E-15C-MRATE, MPC10E-10C-MRATE, MPC4E-3D-2CGE-8XGE, MPC5E-100G10G, MPC-3D-16XGE-SFPP, MIC3-3D-10XGE-SFPP

Tools and parts needed

  • Electrostatic discharge (ESD) grounding wrist strap
  • Electrostatic bag or antistatic mat
  • Rubber safety caps for fiber transceivers and cable ends
  • Blank panels (if component is not reinstalled)
  • A narrow-ended tool for the MIC online/offline button

The maker's warnings

  • A fully configured MPC can weigh up to 18.35 lb (8.3 kg), with the weight in the back end. Be prepared to take its full weight as it leaves the chassis.[S1]
  • Out of the chassis, never hold an MPC by the ejector handles, bus bars, or edge connectors. They cannot support its weight.[S1]
  • Do not stack MPCs on top of one another after removal. Each goes in its own electrostatic bag or on its own antistatic mat.[S1]
  • After removing an MPC, wait at least 30 seconds before reinserting it or inserting an MPC into a different slot, and after the OK/FAIL LED lights steadily, wait at least 30 seconds before removing an MPC again.[S1]
  • Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. The laser light can damage your eyes.[S1]
  • Do not bend a fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable.[S1]
  • Slide a MIC straight into its slot to avoid damaging the components on the MIC.[S1]
  • If an emptied slot will not be refilled within a short time, install a blank panel to keep the airflow right in the card cage.[S1]

Steps

  1. Step 1: Get the bench ready

    Have a replacement MPC or a blank panel ready, an antistatic mat for the card, and a rubber safety cap for each MIC with an optical interface.[S1]

  2. Step 2: Ground yourself and label the cables

    Attach an ESD grounding strap to your bare wrist and an ESD grounding point, then label the cables on each MIC so they go back to the right ports.[S1]

  3. Step 3: Take the old MPC offline

    Press and hold the card's online button on the craft interface until its green OK/FAIL LED goes off, or run request chassis fpc slot slot-number offline.[S1]

  4. Step 4: Disconnect and cap the cables

    Disconnect the cables from the MICs, cover each transceiver and cable end with a rubber safety cap at once, and lay the cables in the cable management brackets.[S1]

  5. Step 5: Unseat and remove the MPC

    Turn both ejector handles counterclockwise together, slide the card halfway out by its handles, then support the front with one hand and the underside with the other and slide it out onto the antistatic mat.[S1]

  6. Step 6: Fit the MICs to the new MPC

    With the new MPC on an antistatic mat, check each fiber MIC has a safety cap, pull the ejector lever next to the MIC slot, align the MIC with the guides at the corners of the slot, slide it straight in until firmly seated, and push the lever back toward the faceplate.[S1]

  7. Step 7: Slide the MPC into the card cage

    Face the faceplate toward you, lift the card into place, align its sides with the guides in the card cage, and slide it all the way in until you feel resistance.[S1]

  8. Step 8: Seat it with the ejector handles

    Grasp both ejector handles and rotate them clockwise together until the MPC is fully seated.[S1]

  9. Step 9: Reconnect the cables

    Remove the safety caps, insert each cable into its port, and dress the cables so none supports its own weight, with extra length in a neat coiled loop.[S1]

  10. Step 10: Bring the MPC online

    Press and hold the card's online button on the craft interface until the green OK/FAIL LED lights steadily, in about 5 seconds, or run request chassis fpc slot slot-number online.[S1]

  11. Step 11: Bring a MIC online on its own

    When you add a MIC to an MPC that is already running, press the MIC offline/online button until the MIC OK/FAIL LED lights green, or run request chassis mic fpc-slot mpc-slot mic-slot mic-slot online.[S1]

  12. Step 12: Verify

    Run show chassis fpc and show chassis fpc pic-status to confirm the MPC is Online and every MIC is listed.[S1]

On a Juniper MX480 the line cards are Modular Port Concentrators (MPCs), and the ports themselves sit on Modular Interface Cards (MICs) that plug into the MPC. Some MPCs are fixed configuration cards that combine packet forwarding and Ethernet interfaces onto a single line card and take no MICs at all. This guide covers what to check before a card goes in, the power each common card draws, how its ports will be named, and Juniper's steps for seating an MPC and a MIC.

Check the chassis before the card arrives

Three things in the chassis decide whether a new MPC will run. First, the cooling: Juniper says you must install a high-capacity fan tray to use an MPC. Second, the control boards: you must install redundant SCBs to support full line-rate. Third, the software: every MPC has a first Junos OS release on the MX240, MX480 and MX960, and the Routing Engine has to run that release or later.

MPCModel numberFirst Junos OS release on MX240, MX480 and MX960
Fixed configuration MPCMPC-3D-16XGE-SFPP10.0R2
2x100GE + 8x10GE MPC4EMPC4E-3D-2CGE-8XGE12.3R2
2x100GE + 4x10GE MPC5EMPC5E-100G10G13.3R3
MPC7E-MRATEMPC7E-MRATE15.1F4 with Junos Continuity, 16.1R1 and later
MPC10E-15C-MRATEMPC10E-15C-MRATE19.1R1
MPC10E-10C-MRATEMPC10E-10C-MRATE19.2R1

The MX480 has six dedicated line card slots for DPCs, MPCs, or FPCs that are numbered 0 through 5 bottom to top, and you can install any combination of line card types in the router. Any slot left without a card needs a blank DPC panel to fill the empty slot and ensure proper cooling of the system.

Power: what each card draws

Add the new card to your power budget before it ships, using Juniper's table of FRU power requirements. Juniper lists these maximum power requirements:

CardMaximum power, from Juniper's table
MPC-3D-16XGE-SFPP440 W at 131° F (55° C) ambient, 423 W at 77° F (25° C) ambient
MPC4E-3D-2CGE-8XGE610 W
MPC5E-100G10G607 W at 131° F (55° C) with optics
MPC7E-MRATE545 W at 131° F (55° C) with optics
MPC10E-10C-MRATE620 W at 131° F (55° C)
MPC10E-15C-MRATE785 W at 104° F (40° C)

For the rest of the budget, the base system needs 40 W and a Routing Engine such as the RE-S-X6-64G needs 110 W. The high-capacity cooling system needs 160 W, but Juniper notes that the cooling system power requirement does not need to be deducted from the output power budget of the power supply, because it comes from a separate tap.

MICs: two per MPC, and the septum

An MPC card carrier, which includes two MIC slots, takes up to two MICs, and they may be different media types as long as the MPC supports those MICs. Juniper publishes MIC and MPC compatibility tables that list the first Junos OS release in which each MPC supports each MIC, and in those tables an en dash indicates that the MIC is not supported. Check your exact MIC against your exact MPC there before you order.

A dual-wide MIC takes up both MIC slots, and between two single MICs sits a septum held by screws in holes labeled S. Going from one dual-wide MIC to two single MICs means fitting the septum with two screws on the top and four on the bottom, and the reverse means taking it out and storing the septum and screws for later use. Either way the MPC comes out of the router onto a flat surface for that work.

How the new ports will be named

On the MX480 router, the MPCs are represented in the CLI as FPC 0 through FPC 5, so the line card slot number is the first number of every interface name on that card. The second number is the logical PIC: numbered 0 or 1 when installed in slot 0, and 2 or 3 when installed in slot 1 of the MPC. The last number is the port on the MIC. A 20-port Gigabit Ethernet MIC, for example, has two logical PICs, numbered 0 and 1 when installed in slot 0, or 2 and 3 when installed in slot 1. Plan your configuration with those numbers before the card goes in, so the interfaces come up already set.

What happens when the card goes in live

MPCs are hot-removable and hot-insertable, and the router keeps forwarding on its other cards while you work. When you install an MPC in an operating router, the Routing Engine downloads the MPC software, the MPC runs its diagnostics, and the Packet Forwarding Engines housed on the MPC are enabled, and forwarding on other MPCs continues uninterrupted during this process. Pulling an MPC stops only its own ports: the MIC interfaces installed on the MPC being removed no longer function. After the swap, the value Online in the State column of show chassis fpc means the MPC is working, and show chassis fpc pic-status shows each MIC.

In stock at Townsend

In stock now are the MPC7E-MRATE, the MPC10E-15C-MRATE and the 2x100GE + 8x10GE MPC4E, with MICs such as the MIC3-3D-10XGE-SFPP on the same shelf. Every MX line card we list is on the MX line card shelf, and the MX480 shelf holds the chassis parts that go with them.

Sources

Checked against the maker's documents on .

  1. S1Maintaining MX480 Interface ModulesJuniper Networks · Document: MX480 Universal Routing Platform Hardware Guide · Revision: Topic page dated 2025-06-29 · Section: Maintaining MX480 MPCs; Replacing an MX480 MPC; Maintaining MX480 MICs; Replacing an MX480 MIC · June 29, 2025

  2. S2MX480 Interface Modules: MPCs and MICsJuniper Networks · Document: MX480 Universal Routing Platform Hardware Guide · Revision: Topic page dated 2025-10-06 · Section: MIC/MPC Compatibility; MX480 MIC Port and Interface Numbering; MX480 Modular Port Concentrator (MPC) Description; MPCs Supported by MX Series Routers (Table 13) · October 6, 2025

  3. S3MX480 Power PlanningJuniper Networks · Document: MX480 Universal Routing Platform Hardware Guide · Revision: Topic page dated 2025-09-29 · Section: Power Requirements for an MX480 Router (Tables 1 and 3) · September 29, 2025

  4. S4Maintaining MX480 ComponentsJuniper Networks · Document: MX480 Universal Routing Platform Hardware Guide · Revision: Topic page dated 2024-09-11 · Section: MX480 Field-Replaceable Units (FRUs); Tools and Parts Required to Replace MX480 Hardware Components · September 11, 2024

In stock now

MPC7E-MRATE Juniper Line Card, Refurbished, 8x 10/40GbE QSFP+ and 4x 10/40/100GbE QSFP28

MPC7E-MRATE

MPC7E-MRATE Juniper Line Card, Refurbished, 8x 10/40GbE QSFP+ and 4x 10/40/100GbE QSFP28

In stock

$9,500Ships same day
MPC10E-15C-MRATE Juniper Line Card, Refurbished, 12x 10/25/40/100GbE QSFP28 and 3x 400GbE QSFP56-DD

MPC10E-15C-MRATE

MPC10E-15C-MRATE Juniper Line Card, Refurbished, 12x 10/25/40/100GbE QSFP28 and 3x 400GbE QSFP56-DD

In stock

$26,725Ships same day
MPC4E-3D-2CGE-8XGE Juniper Line Card, Refurbished, 8x 10GbE SFP+ and 2x 100GbE CFP

MPC4E-3D-2CGE-8XGE

MPC4E-3D-2CGE-8XGE Juniper Line Card, Refurbished, 8x 10GbE SFP+ and 2x 100GbE CFP

In stock

$1,240Ships same day
MIC3-3D-10XGE-SFPP Juniper MIC, Refurbished, 10x 10GbE SFP+

MIC3-3D-10XGE-SFPP

MIC3-3D-10XGE-SFPP Juniper MIC, Refurbished, 10x 10GbE SFP+

In stock

$150Ships same day

Need help planning your next move?

Tested, warrantied hardware with real availability, and cash offers for decommissioned gear. Quotes answered by a human.